Sabaragamuwa University of Sri Lanka

Use of Passive Air Sampling Technique to Monitor Air Quality Levels in Protected Areas: A Case Study in Horton Plains National Park

Show simple item record

dc.contributor.author Ranathunga, R. A. D. C
dc.contributor.author Kudavidanage, E. P
dc.contributor.author Premasiri, H. D. S
dc.date.accessioned 2021-01-05T12:51:46Z
dc.date.available 2021-01-05T12:51:46Z
dc.date.issued 2017-12-13
dc.identifier.uri http://repo.lib.sab.ac.lk:8080/xmlui/handle/123456789/181
dc.description.abstract Horton Plains National Park (HPNP) is an ecologically sensitive area; therefore, utilization of such an area should involve a high consideration on environmental safeguarding. Visitor statistics of HPNP clearly indicate that the number of visitors is in increasing trend and parallel increment of vehicles entering the park each year. But, the park does not have any regular air quality management system in place yet and the past measurements of air pollution have been done on an ad hoc basis. In this context, the necessity to carry out a study to determine current levels of Nitrogen Dioxide (NO2) and Sulfur Dioxide (SO2) concentrations in ambient air in the National Park and initiation of an ambient air quality database was identified. This research work describes the determination of levels of NO2 and SO2 at HPNP using of passive sampling technique. Ambient levels of these pollutants were monitored in twelve sites including two background sites from 9th November 2016 to 31st January 2017 at two weeks’ intervals. There was a significant strong positive relationship between the results obtained by duplicate sampling of passive sampling device. Highest variation of both NO2 and SO2 was observed in the Ohiya road ranging from 1.02 μg/m3 to 6.41 μg/m3 and 4.75 μg/m3 to 21.14 μg/m3 respectively. The highest two weeks mean concentrations of NO2 and SO2 were recorded at the Car park and Pattipola road with values of 3.67 ± 1.92 μg/m3 and 17.68 ± 4.58 μg/m3 respectively. The lowest two weeks mean concentrations of NO2 and SO2 were recorded in undisturbed forest site (background site) and forest die back site with values of 0.95 μg/m3 ± 0.38 and 2.91 ± 1.56 μg/m3 respectively. Ambient NO2 concentrations of 6.41 μg/m3 and 0.32 μg/m3 were recorded as Highest and lowest levels for the entire data collection period respectively for Ohiya road and background site. Highest and lowest SO2 levels of 25 μg/m3 and 1.32 μg/m3 were obtained for the Pattipola road site and the background site. Results indicate that the measured air pollutant levels in HPNP currently are very low and do not exceeded the Sri Lankan ambient air quality standards. Furthermore, correlations of ambient pollutant levels (NO2, SO2) with visitor presence, rainfall, temperature and relative humidity were also investigated in this study. en_US
dc.language.iso en_US en_US
dc.publisher Sabaragamuwa University of Sri Lanka en_US
dc.subject Air Pollution en_US
dc.subject Horton Plains National Park en_US
dc.subject Nitrogen Dioxide en_US
dc.subject Passive Sampling en_US
dc.subject Sulphur Dioxide en_US
dc.title Use of Passive Air Sampling Technique to Monitor Air Quality Levels in Protected Areas: A Case Study in Horton Plains National Park en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

  • ARS 2017 [52]
    Annual Research sessions held in the year 2017

Show simple item record

Search DSpace


Advanced Search

Browse

My Account