Sabaragamuwa University of Sri Lanka

IDENTIFICATION OF FACTORS LEADING TO TEE SPOILAGE OF STERILIZED MILK

Show simple item record

dc.contributor.author Wicramarathne, W.
dc.date.accessioned 2022-11-16T09:22:05Z
dc.date.available 2022-11-16T09:22:05Z
dc.date.issued 2005-06
dc.identifier.uri http://repo.lib.sab.ac.lk:8080/xmlui/handle/susl/2835
dc.description.abstract Milk and milk products are an important as they gain demand because of its nutritional and organoleptic properties. Milk is perfect medium for microorganism to grow that favours it’s resulting in subsequent spoilage. Thus, bacteria can easily be attracted and can rapidly multiply. Hence, in milk industry milk processing plays a major role leading to the enhancement of keeping quality of milk. The microbial count of 1ml of raw milk is normally uncountable. Heat processing is done to bring this count to a lower safer level. Sterilized milk bottles shelf life is about 5 months. Normally commercial sterilization, spores are present 1 bottle out of 100. If milk bottles retain, bacteria it leads to the curdling of bottles. They may be post contaminated or process operation problem may retain bacteria spores in sterilized bottled. Curdled bottles were taken and identified the presence of bacteria by using culture techniques. After that gram staiftmg. test was done for differentiation of bacteria either gram negative or gram positive. Degree of contamination was determined by drawing sample from all stages in process line and through following enumeration of TCC, Td and Tp bacteria. Sterilized bottles were incubated various temperature and identified the optimum temperature for curdling of bottes.55-60 °C range is considered to this most suitable temperature. Changing of the pH acidity in curdles bottles reflects presence of bacteria in bottles. This variation was identified by measuring the pH and acidity in curdle and normal bottles. The bottles may contaminated by remaining spores if washing process is inefficient. Therefore, the strength of washing tanks (pre soak and main soak) has been calculated. These calculations were done every testing day. After washing the remaining causticities were identified by adding the drop of phenolphthalein. Samples were collected to be determining the process temperature variability this was done 3 times per day. The Changing in bottle sterilization method using autoclave lead to the poor time- temperature combination exposure to all the sterilized bottles. After the incubation at 55°C period, autoclave sterilized bottles were not curdle that identified. The heat treatment of milk causes some changes in the properties of mi lk depending upon the time temperature combination. en_US
dc.language.iso en en_US
dc.title IDENTIFICATION OF FACTORS LEADING TO TEE SPOILAGE OF STERILIZED MILK en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account