Sabaragamuwa University of Sri Lanka

Secondary Verification of Calculated Treatment Time for Co-60 External Beam Planning System

Show simple item record

dc.contributor.author Navodya, K.A.H.
dc.contributor.author Madushan, P.A.S.
dc.contributor.author Ruvinda, K.K.D.L.
dc.contributor.author Kumara, K.V.A.W.
dc.contributor.author Bandara, N.S.
dc.contributor.author Fernando, W.T.L.S.
dc.date.accessioned 2023-10-26T03:54:16Z
dc.date.available 2023-10-26T03:54:16Z
dc.date.issued 2023-05-30
dc.identifier.isbn 978-624-5727-37-7
dc.identifier.uri http://repo.lib.sab.ac.lk:8080/xmlui/handle/susl/4063
dc.description.abstract In radiotherapy, it requires accurately calculated radiation dose to reach maximum success in radiation treatments. Although Co-60 is widely used in certain applications of therapeutic treatments of cancer, it is mandatory to have a treatment planning system (TPS) to estimate reliable radiation dose on the targeted area. Along with that purpose, this study focused on building up a system to estimate the treatment time by analyzing 2D computed tomography (CT) images. In such a treatment system, it is important to identify the effective depth to the tumor from the patient’s surface, as it affects the estimated treatment time. Axial 2D chest CT images were analyzed using Python programming language to find the specific regions along the beam path to obtain the effective depth while the estimation of treatment time was carried out using the source to tumor distance (STD) setup. Estimated treatment time using this new system shows significant variance compared to the existing system which estimates the treatment time without considering the inhomogeneous materials in our body. It can be attributed as such a variance is due to the consideration of different values of attenuation in tissues or inhomogeneous materials which were obtained through the analyzed CT scan images to the beam from the new system while attenuation values are considered to be equivalent to water in the present system. With these results, this study revealed that different attenuation values from inhomogeneous materials largely affect radiation treatment time estimation. en_US
dc.language.iso en en_US
dc.publisher Sabaragamuwa University of Sri Lanka en_US
dc.subject Co-60 en_US
dc.subject 2D CT Image en_US
dc.subject Source to Tumor Distance (STD) Setup en_US
dc.subject Treatment Time en_US
dc.subject Treatment Planning System (TPS) en_US
dc.title Secondary Verification of Calculated Treatment Time for Co-60 External Beam Planning System en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account